草草国产成人免费视频_日韩欧洲旡码专区在线_日夜男女高清在线免费观看_亚洲另类春色小说_国产日韩欧美在线看_国产日韩一区在线精品_狠狠色综合网丁香五月_综合精品二区国产中文字幕_小说专区亚洲春色校园_少妇人妻激情按摩系列

Industry TrendsABOUT US
Construction plan of extruded board
2023-02-24

Extruded board prepares special construction plan, labor demand plan and organizes construction team to enter the site, and reports to the supervisor and construction unit for approval. According to the determined installation layout, use the total station to pop up control points and lines on the exterior wall. Due to the capillary action in the wall, it is absorbed into the insulation layer, resulting in a negative impact on the life and effect of the insulation layer. For the parts where the deformation joints exist in the base wall, corresponding deformation joints must be left in the insulation layer.


If there are uneven joints in the construction plan of the extruded board, it should be polished with coarse sandpaper lined with flattening treatment. The polishing action should be a gentle circular motion, and do not polish in the direction parallel to the joints of the extruded board. After polishing, use a brush or compressed air to clean up the debris and other floating dust generated by the polishing operation. Use adhesive to apply a circle of adhesive around the extruded board surface, with a width of 50mm; the board core is arranged with bonding points in a plum blossom shape, with a spacing of 150mm-200mm and a diameter of 100mm. The standard layer of extruded board bonding area should be no less than 70%, and the thickness of the bonding layer should be able to level the extruded board bonding layer.


In the construction plan of the extruded board, the construction quality of the base wall, cement mortar leveling layer and door and window openings should be accepted, and the door and window frames or sub-frames should be installed in place. Embedded parts such as fire ladders, downspouts, pipelines passing through the wall openings and air conditioners extending out of the wall. There are corresponding standards for the number and fixing depth of each thermal insulation decorative integrated panel. Generally, the depth should not be less than 25 mm, and the number should not be less than 3. The filling width and filling depth of the foam filler at the deformation joint should meet the corresponding standard requirements. Since the slight unevenness and roughness of the base wall can be adjusted by special mortar, the flatness and finish of the thermal insulation decorative board to the base are relatively low, and the treatment is relatively simple.